Test Code GLURDM Glucose Level Random
Additional Codes
Cerner |
NextGen |
Glucose Level Random |
Glucose Level Random |
Glu |
|
Alternate Name(s)
Random Blood Sugar
Useful For
Glucose is a primary cellular energy source. Fasting plasma glucose concentrations and tolerance to a dose of glucose are used to establish the diagnosis of diabetes mellitus and disorders of carbohydrate metabolism. Glucose measurements are used to monitor therapy in diabetics and in patients with dehydration, coma, hypoglycemia, insulinoma, acidosis, and ketoacidosis.
Methodology
Colorimetric (reflectance spectrophotometry) using Glucose Oxidase.
Patient Preparation
None
Collection Instructions
Standard phlebotomy practices.
Specimen Requirements
Container |
|
||||||||||||
Stability |
|
||||||||||||
Rejection Criteria |
Gross Hemolysis |
Result Reporting and Reference Values
Reported in mg/dL.
Age |
Low |
High |
Critical Low |
Critical High |
0-2days |
40 |
90 |
40 |
300 |
2days-30days |
60 |
105 |
40 |
300 |
30days-18years |
60 |
105 |
50 |
500 |
18-150 year |
74 |
118 |
50 |
500 |
Reflex Testing
None
Limitations
- Ortho reports a bias with the following:
- Glutathione at 61.5 mg/dL has a -8.6 bias
- Ortho reports no significant interference with the following:
- Bilirubin at 40 mg/dL