Test Code F68KD 68kD (hsp-70) antibodies by Line Blot
Reporting Name
68kD (hsp-70) antibodiesPerforming Laboratory
IMMCO Diagnostics, Inc.Specimen Type
SerumSpecimen Required
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 3 mL Serum
Collection Instructions:
1. Centrifuge and aliquot serum into a plastic vial.
2. Send frozen.
Specimen Minimum Volume
Serum: 2 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Frozen (preferred) | 365 days |
| Refrigerated | 5 days | |
| Ambient | 48 hours |
Reference Values
Qualitative test-Positive or Negative
Day(s) Performed
Once per week
CPT Code Information
84182
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| F68KD | 68kD (hsp-70) antibodies | 43597-4 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| Z0909 | 68kD (hsp-70) antibodies | 43597-4 |
Report Available
3 to 18 daysTest Classification
This test has been developed and performance parameters have been validated by IMMCO Diagnostics, Inc. This test has not been approved by the U.S. Food and Drug Administration (FDA); however, US FDA approval is not required for clinical use. It is not intended that clinical diagnosis and patient management decisions be made using these results alone. This test has been validated using serum samples. The manufacturer has not determined the efficacy of this test when performed on CSF, plasma, joint or pleural fluid specimens. The performance characteristics of this test were determined by IMMCO Diagnostics Inc.Interpretation
Antibodies to inner ear antigen (68kDa) occur in approximately 70% of patients with autoimmune hearing loss. The antibody tests to this 68kDa antigen parallel with disease activity. In addition, a majority of patients positive for antibodies to 68kDa are responsive to corticosteroid treatment.(Hirose et al. The Laryngoscope. 109:1769-1999)
Method Name
Line Immunoassay
Reject Due To
All specimens will be evaluated by the processing and performing laboratories for test suitability.Clinical Information
Refer to www.immco.com/otology/