Sign in →

Test Code ARBI Acetylcholine Receptor (Muscle AChR) Binding Antibody, Serum

Reporting Name

ACh Receptor (Muscle) Binding Ab

Useful For

Supporting the diagnosis of autoimmune myasthenia gravis (MG) in adults and children

 

Distinguishing autoimmune from congenital MG in adults and children or other acquired forms of neuromuscular junction transmission disorders

 

An adjunct to the test for P/Q-type calcium channel binding antibodies as a diagnostic aid for Lambert-Eaton myasthenic syndrome

Testing Algorithm

This is the primary diagnostic test for myasthenia gravis.

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Ordering Guidance


Standalone testing (this test) is recommended in certain situations.

 

This test should not be requested in patients who have recently received radioisotopes, therapeutically or diagnostically, because of potential assay interference. The specific waiting period before specimen collection will depend on the isotope administered, the dose given, and the clearance rate in the individual patient. Specimens will be screened for radioactivity prior to analysis. Radioactive specimens received in the laboratory will be held for 1 week and assayed if sufficiently decayed or canceled if radioactivity remains.



Specimen Required


Patient Preparation: For optimal antibody detection, specimen collection is recommended prior to initiation of immunosuppressant medication.

Supplies: Sarstedt Aliquot Tube 5 mL (T914)

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1.5 mL


Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days
  Frozen  28 days
  Ambient  72 hours

Reference Values

≤0.02 nmol/L

Day(s) Performed

Monday through Sunday

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

86041

LOINC Code Information

Test ID Test Order Name Order LOINC Value
ARBI ACh Receptor (Muscle) Binding Ab 97558-1

 

Result ID Test Result Name Result LOINC Value
8338 ACh Receptor (Muscle) Binding Ab 97558-1

Clinical Information

Fatigable weakness due to impaired postsynaptic transmission at the neuromuscular junction is characteristic of myasthenia gravis (MG). A clinical diagnosis should be supported by electrodiagnostic testing (ie, clinical-electrodiagnosis [EDX]). Positive autoimmune serology increases certainty of MG diagnosis but needs to be interpreted in the proper clinical-EDX context with response to anticholinesterase medications supporting the diagnosis. Most cases are autoimmune and are caused by IgG autoantibodies binding to critical postsynaptic membrane molecules (nicotinic muscle acetylcholine receptor [AChR] or its interacting proteins, such as muscle-specific kinase). Serologically, the detection of AChR binding antibody provides the best diagnostic sensitivity. However, the presence of both AChR binding and modulating activity improves diagnostic accuracy. Autoantibody detection frequency is lowest in patients with weakness confined to extraocular muscles (approximately 70% are positive for AChR binding antibodies) and highest in patients with generalized weakness due to MG (approximately 90% are positive for AChR binding antibodies). In adults with MG and AChR antibodies, approximately 20% will have thymoma and, very rarely (<1%), extrathymic cancers. Computed tomography imaging of the chest is considered the standard of care to evaluate for thymoma.

 

These results should only be interpreted in the appropriate clinical and electrophysiological context and are not diagnostic in isolation.

 

Note: Single antibody tests may be requested in the follow-up of patients with positive results previously documented in this laboratory.

Interpretation

Positive results (>0.02 nmol/L) are indicative of autoimmune myasthenia gravis (MG). These results should be interpreted in the appropriate clinical and electrophysiological context.

 

With a diagnosis of MG, a paraneoplastic basis should be considered with thymoma being the most frequently associated tumor with MG.

 

The clinical sensitivity of this assay is approximately 90% in nonimmunosuppressed patients with generalized MG. The frequency of antibody detection is lower in MG patients with weakness clinically restricted to ocular muscles (71%), and antibody titers are generally low in ocular MG (eg, 0.03-1.0 nmol/L).

 

Negative results do not exclude the diagnosis of MG. If clinical suspicion remains and symptoms persist or worsen consider retesting. Results may be negative in the first 12 months after symptoms of MG appear or during immunosuppressant therapy. Note: In follow up of seronegative patients with adult-acquired generalized MG, 17.4% seroconvert to positive at 12 months (ie, seronegativity rate at 12 months is 8.4%). A subset of MG patients that are persistently negative for acetylcholine receptor binding antibodies will have muscle-specific kinase (MuSK) antibodies, and therefore, it is recommended to test for MuSK antibodies in seronegative patients with high clinical suspicion of MG.

 

In general, there is not a close correlation between antibody titer and severity of weakness, but in individual patients, clinical improvement may be accompanied by a decrease in titer.

Report Available

3 to 6 days

Specimen Retention Time

28 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Method Name

Radioimmunoassay (RIA)

Forms

If not ordering electronically, complete, print, and send a Neurology Specialty Testing Client Test Request (T732) with the specimen.

Secondary ID

8338