Test Code 5BETH Factor V Bethesda Units, Plasma
Ordering Guidance
If type of inhibitor is unknown, order APROL / Prolonged Clot Time Profile, Plasma.
Specimen Required
Only orderable as a reflex. For more information see:
-ALUPP / Lupus Anticoagulant Profile, Plasma
-ALBLD / Bleeding Diathesis Profile, Limited, Plasma
-APROL / Prolonged Clot Time Profile, Plasma
-5INHE / Factor V Inhibitor Evaluation, Plasma
Secondary ID
607433Useful For
Detecting and quantifying the presence and titer of a specific factor inhibitor directed against coagulation factor V
Method Name
-ALUPP / Lupus Anticoagulant Profile, Plasma
-ALBLD / Bleeding Diathesis Profile, Limited, Plasma
-ACBL / Bleeding Diathesis Profile, Comprehensive, Plasma
-APROL / Prolonged Clot Time Profile, Plasma
-5INHE / Factor V Inhibitor Evaluation, Plasma
Optical Clot-Based
Reporting Name
FV Bethesda Units, PSpecimen Type
Plasma Na CitSpecimen Stability Information
| Specimen Type | Temperature | Time | 
|---|---|---|
| Plasma Na Cit | Frozen | 14 days | 
Reject Due To
| Gross hemolysis | Reject | 
| Gross lipemia | Reject | 
| Gross icterus | Reject | 
Clinical Information
Significant bleeding can result from the presence of a coagulation factor inhibitor and could be life threatening. Whether the inhibitor is present due to hemophilia or is of an acquired nature, it greatly complicates the treatment process of a decreased factor level. The titer of the inhibitor may determine the mode of treatment. Bethesda units are a standardization to give a uniform definition of an inhibitor.
Reference Values
Only orderable as a reflex. For more information see:
-ALUPP / Lupus Anticoagulant Profile, Plasma
-ALBLD / Bleeding Diathesis Profile, Limited, Plasma
-ACBL / Bleeding Diathesis Profile, Comprehensive, Plasma
-APROL / Prolonged Clot Time Profile, Plasma
-5INHE / Factor V Inhibitor Evaluation, Plasma
≤0.5 Bethesda Units
Interpretation
An interpretive report will be provided when testing is complete.
Day(s) Performed
Monday through Friday
Report Available
2 to 5 daysPerforming Laboratory
 Mayo Clinic Laboratories in Rochester
 Mayo Clinic Laboratories in Rochester
Test Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
85335
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value | 
|---|---|---|
| 5BETH | FV Bethesda Units, P | 3191-4 | 
| Result ID | Test Result Name | Result LOINC Value | 
|---|---|---|
| 607433 | FV Bethesda Units, P | 3191-4 | 
 
           Home
Home Help
Help