Test Code 21OH 21-Hydroxylase Antibodies, Serum
Ordering Guidance
Testing for autoantibodies against 21-hydroxylase is recommended following confirmation of adrenal insufficiency to help differentiate between causes of primary adrenal insufficiency
Shipping Instructions
Ship specimen frozen on dry ice
Specimen Required
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial to remove from cells or gel prior to shipping.
Secondary ID
607788Useful For
Investigating adrenal insufficiency
Aiding in the detection of those at risk of developing autoimmune adrenal failure in the future
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)
Reporting Name
21-Hydroxylase Ab, SSpecimen Type
SerumSpecimen Minimum Volume
0.2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Frozen | 14 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Clinical Information
Adrenal insufficiency is caused by failure of the adrenal cortex to produce cortisol. This failure can result from loss of function of the adrenal glands (ie, primary adrenal insufficiency). This is most frequently caused by autoimmune adrenalitis or Addison disease accounting for 68% to 94% of cases. It can occur sporadically or in combination with other autoimmune endocrine diseases that together comprise type I or II autoimmune polyglandular syndrome (APS).
Antibodies that react with several steroidogenic enzymes (most often 21-hydroxylase) are present in the serum of up to 86% of patients with autoimmune primary adrenal insufficiency but only rarely in patients with other causes of adrenal insufficiency. Therefore, 21-hydroxylase autoantibodies are markers of autoimmune Addison disease, whether present alone or as part of type I or II APS. The measurement of 21-hydroxylase autoantibodies is an important step in the investigation of adrenal insufficiency and may aid in the detection of those at risk of developing autoimmune adrenal failure in the future.
Reference Values
Negative
Interpretation
This is a qualitative test. A positive result indicates the presence of autoantibodies to 21-hydroxylase and is consistent with Addison disease.
Utilizing an index value of <45 as a negative cutoff, this assay has a clinical sensitivity and specificity of 87.0% (95% CI: 79.4%-92.2%) and 99.3% (95% CI: 97.5%-99.8%), respectively.
Day(s) Performed
Wednesday
Report Available
3 to 9 daysSpecimen Retention Time
2 weeksPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
83516
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
21OH | 21-Hydroxylase Ab, S | 85363-0 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
607788 | 21-Hydroxylase Ab, S | 85363-0 |